Three Phase Heater Current Calculation
Enter the phase to phase v ll voltage for a 3 phase ac supply in volts.
Three phase heater current calculation. Rated kw factors rated voltage applied voltage. Do not use typical power factor values for accurate calculations. To calculate kva you need to enter the known values of voltage and the current into the respective fields. The voltage v in volts v is equal to the current i in amps a times the resistance r in ohms ω.
Line current 1 phase amps kw x 1000. Chromalox is a thermal technology company. User manuals specification sheets cad drawings and more. Leverage watlow s growing toolkit of calculators equations reference data and more to help design your thermal system.
The three phase power calculator calculates the active and reactive power current from the following parameters. Locate actual applied voltage. Calculate reset. I a 1000 p kw 3 pf v l n v typical power factor values.
Locate heater rated voltage. You still have your three phase system with the current in each line being slightly different if all the line currents were the same it would just be a balanced three system. For both wye and delta balanced loads wye and delta equivalent. Volts x 1 73 applied vs.
Ac ohm s law calculator. In the a phase you have 80 6a b phase 65 8a and c phase 73 2a that s it. We engineer thermal solutions for the world s toughest industrial heating applications. The phase current i in amps a is equal to 1000 times the power p in kilowatts kw divided by 3 times the power factor pf times the line to neutral rms voltage v l n in volts v.
Volts line current 3 phase amps kw x 1000. Typical 3 phase wiring diagrams and equations for resistive heaters definitions. Amps kw 1 000 3 pf volts for example find the current of a 25kw three phase generator with an efficiency of 80 at 240 volts. The three phase current as you are trying to calculate it does not exist.
Single three phase line kva calculator is an online tool used in electrical engineering to measure the unknown quantity by two known quantities applied to the below formulas for single phase and three phase connection. V p phase voltage v l line voltage i p phase current i l line current r r1 r2 r3 resistance of each branch w wattage w delta 3 w wye w odelta w delta w owye w wye. The formula to find amps for a three phase ac circuit is a little different than the formula for a single phase circuit. 120 208 220 230 240 277 440 460 480.
Ohm s law calculator 3 phase delta wye calculator.